HGU-12V — Drop-In Replacement 12 V Monobloc for UPS, Alarm and Security

  • Model: HGU12-4.5 – HGU12-250 (34 models)
  • Specification: AGM VRLA 12 V monobloc, 4.5 – 250 Ah
  • Size: 90 × 70 × 101 mm (HGU12-4.5) up to 522 × 268 × 220 mm (HGU12-250)
  • Weight: On datasheet
  • Description: HGU-12V — The Drop-In Replacement 12 V Monobloc for Every Small UPS and Alarm Panel34 sealed 12 V AGM models from 4.5 Ah to 250 Ah — the everyday replacement monobloc for UPS, EPS and securityIf you maintain a fleet of small UPS units, fire-alarm panels, access-control boards or telecom FTTx nodes
  • Online ordering

HGU-12V — The Drop-In Replacement 12 V Monobloc for Every Small UPS and Alarm Panel

34 sealed 12 V AGM models from 4.5 Ah to 250 Ah — the everyday replacement monobloc for UPS, EPS and security

If you maintain a fleet of small UPS units, fire-alarm panels, access-control boards or telecom FTTx nodes, the HGU-12V monobloc is the 12 V battery you can stock once and use everywhere. Thirty-four capacity steps between 4.5 Ah and 250 Ah, all on the same AGM recipe, all using the same F1/F2/F3/F12/F16/F20 terminal families. Pull a 12 Ah off the shelf for an office UPS today, a 100 Ah tomorrow for a small telecom cabinet — the float voltage is identical and the commissioning card is identical.

Request a Quote →

What is the HGU-12V?

The HGU-12V is the small-form-factor 12 V AGM monobloc family within the HGU platform. It uses absorbed-glass-matt separator, a one-way pressure-relief valve with flame arrester, and a flame-retardant ABS case. Capacity covers the full small-stationary range from 4.5 Ah (a typical alarm panel draws less than 0.5 A in standby) to 250 Ah (a small telecom cabinet or edge-IT rack). All models share the same float voltage of 13.5 V at 25 °C, the same equalise ceiling of 14.4 V, and the same low self-discharge rate, so a single charger setting works across the whole range.

  • 34 capacity steps from 4.5 Ah to 250 Ah (C20, 10.5 V end voltage)

  • AGM VRLA — sealed, no topping-up

  • Float design life 8–12 years at 25 °C (model-dependent)

  • Low self-discharge, recoverable from deep discharge

  • Common terminal families F1/F2/F3/F12/F16/F20

  • CE / UL / IEC 60896-21/22 documentation pack

Where HGU-12V fits

HGU-12V monoblocs drop into virtually any 12 V backup slot you already have:

  • Home-office and small-business UPS (0.5–3 kVA)

  • EPS and emergency-lighting driver boards

  • Fire-alarm, access-control and intruder-detection panels

  • Telecom FTTx nodes, ONT cabinets and small base stations

  • SCADA RTUs, weigh scales, gas-metering and instrumentation

  • Mobility scooters, kids' ride-on toys, e-bike spare battery

  • POS terminals, ticketing machines and small kiosks

Why choose the HGU-12V series

1. One AGM recipe across all 34 models

  • AGM separator, pressure-relief valve and flame arrester on every cell

  • Float voltage 13.5 V at 25 °C, equalise 13.8–14.4 V

  • Common terminal families simplify spare-parts stocking

  • Identical commissioning card across the whole range

2. Right-sized capacity from 4.5 Ah to 250 Ah

  • 4.5–9 Ah models for alarm panels, kids' UPS and small instrumentation

  • 12–55 Ah models for security, mid-size UPS and POS backup

  • 65–250 Ah models for telecom cabinets, edge IT and small solar storage

  • 17–250 Ah models available with front-access M5/M6 terminal option

3. Long shelf life, recoverable from deep discharge

  • Self-discharge below 3 % per month at 25 °C — keeps the spare on the shelf ready

  • Recovers from deep discharge when re-charge starts within 24 hours

  • Re-charge interval 6 months at 25 °C, 3 months at 35 °C

4. Manufactured for export with full documentation

  • CE / UL / IEC 60896 compliance pack shipped with every order

  • UN2800 non-spillable classification — eligible for air, sea and road freight

  • Laser-etched date code and batch traceability

  • Three-year warranty from date of shipment

Common platform across the HGU-12V family

  • AGM VRLA chemistry — sealed, maintenance-free

  • Float voltage 13.5 V at 25 °C (13.38 V at 20 °C)

  • Equalise / cycle charge 13.8–14.4 V

  • Operating temperature -20 °C to +45 °C (recommended 20–25 °C)

  • Self-discharge below 3 % per month at 25 °C

  • Container and cover ABS, flame-retardant to UL94 V-0 on request

  • One-way pressure-relief valve with flame arrester

  • Cycle life ≥ 1500 cycles at 50 % DoD (model-dependent)

All 34 HGU-12V models at a glance

Dimensions in millimetres; case colour black throughout

ModelVAh (C20)LengthWidthHeightTotal HTerminalCase
HGU12-4.5124.59070101107F1/F2Black
HGU12-5.0125.09070101107F1/F2Black
HGU12-5.5125.59070101107F1/F2Black
HGU12-6.0126.01516594100F1/F2Black
HGU12-6.5126.51516594100F1/F2Black
HGU12-7.0127.01516594100F1/F2Black
HGU12-7.5127.51516594100F1/F2Black
HGU12-8.0128.01516594100F1/F2Black
HGU12-8.5128.51516594100F1/F2Black
HGU12-9.0129.01516594100F2Black
HGU12-1212121519894100F1/F2Black
HGU12-1412141519894100F1/F2Black
HGU12-171217181.576.5166.5166.5F1/F2Black
HGU12-181218181.576.5166.5166.5F1/F2Black
HGU12-201220181.576.5166.5166.5F3Black
HGU12-241224166126175175F12Black
HGU12-261226166126175175F12Black
HGU12-331233195130158166F16Black
HGU12-351235195130158166F16Black
HGU12-381238197166168.5168.5F16Black
HGU12-481248197166168.5168.5F16Black
HGU12-501250198166169169F16Black
HGU12-551255229138208214F16Black
HGU12-651265348167177177F16Black
HGU12-701270348167177177F16Black
HGU12-801280260168211217F16Black
HGU12-901290306.5168211217F16Black
HGU12-10012100330173213.5220.5F16Black
HGU12-11012110330173213.5220.5F16Black
HGU12-12012120408177224224F20Black
HGU12-15012150483170239.5239.5F20Black
HGU12-18012180532207214220F20Black
HGU12-20012200522239221223F20Black
HGU12-25012250522268220226F20Black

Operating conditions

  • Float voltage: 13.5 V at 25 °C (temperature-compensated -18 mV/°C/cell)

  • Equalise charge: 13.8–14.4 V for 24 h maximum

  • Operating temperature: -20 °C to +45 °C (recommended 20–25 °C)

  • Self-discharge: below 3 % per month at 25 °C

  • Storage: re-charge every 6 months at 25 °C

  • Torque on terminal bolts: 4–6 N·m (F1/F2/F3), 6–8 N·m (F12/F16), 10–12 N·m (F20)

Application notes

  • For float standby at 25 °C, expect 8–12 years of design life depending on model

  • For cyclic use, expect 1500+ cycles at 50 % depth of discharge

  • For high-rate discharge (UPS duty), check the HGUX family — it is built specifically for 15-minute ride-through

  • For front-access installation in a 19-inch cabinet, check the HGUF family

Other HGU battery families

Why HG upsboss

HG upsboss is the export brand of Shenzhen Shengpuwei Industrial Co., Ltd., a battery and UPS-systems manufacturer based in Shenzhen, China. We design, build and export VRLA, GEL, lead-carbon and LiFePO4 backup batteries for UPS, EPS, telecom, data-centre and renewable-storage operators in more than 60 countries. Every HGU-series battery ships with type-test reports, full BMS integration where applicable, and the CE / UL / IEC documentation you need for customs clearance and end-user acceptance.

Data security and compliance notice

All product specifications, images and documentation published on this page are the property of HG upsboss / Shenzhen Shengpuwei Industrial Co., Ltd. and are intended for legitimate procurement, engineering and integration use. Reproduction for counterfeit, misbranding or unauthorised resale is prohibited. Specification values are typical at 25 °C and may vary within published tolerances. Battery installations must comply with local electrical, ventilation and transport regulations.

Frequently asked questions

1. Can I swap an HGU-12V cell for a different brand in an existing UPS?

Yes — the HGU-12V monobloc is built to industry-standard footprints and uses the common F1/F2/F3/F12/F16/F20 terminal families. As long as the original cell is also an AGM VRLA monobloc with the same nominal voltage and capacity within ±10 %, the swap is a direct mechanical and electrical replacement.

2. What is the difference between the small (4.5–9 Ah) and the mid (12–55 Ah) models?

The 4.5–9 Ah models use the 90 × 70 mm or 151 × 65 mm case and F1/F2 tabs — typical of alarm panels and small UPS. The 12–55 Ah models use the 151 × 98 mm or 197 × 166 mm case with F1/F2/F3/M5 tabs — typical of mid-size UPS and access-control panels. Both share the same float voltage.

3. Can HGU-12V batteries be mounted on their side?

Yes — the VRLA AGM construction is fully orientation-tolerant. For best practice, mount upright where possible to keep the valve path clear, but horizontal or end-mount orientations are accepted by the cell manufacturer.

4. How long can an HGU-12V sit on a warehouse shelf?

Factory-fresh HGU-12V monoblocs self-discharge below 3 % per month at 25 °C, so a typical 12-month storage cycle is acceptable without re-charge. After 12 months, a refresh charge at 13.8–14.4 V for 24 hours restores full capacity.

5. Is there a 12 V monobloc for outdoor cabinets?

The standard HGU-12V case is ABS — rated for indoor or sheltered outdoor use. For direct outdoor exposure (sun, rain, salt spray), we recommend the HGUG tubular GEL family, which is built for harsher thermal cycling.

6. Do you make 6 V or 8 V versions?

The HGU platform's 2 V cell family covers 6 V (3-cell) and 8 V (4-cell) configurations by stringing the 2 V cells. For monobloc 6 V / 8 V only, please contact us for a special-build quote.

7. Can I get a higher-capacity version of a popular case size?

The HGU-12V range is the result of several rounds of case-density optimisation. If you need more capacity in a fixed footprint (e.g. 100 Ah in a 12 V monobloc), the 2 V HGU Series cells or the HGUX high-power family offer better energy density.

8. What's the difference between HGU-12V and HGUX?

HGU-12V is the everyday standby monobloc, optimised for 20-hour capacity. HGUX is the high-power family optimised for 5-minute and 15-minute discharge at much higher current — built specifically for UPS ride-through.