Seven VRLA and lithium families, 79 backup battery models, 2 V to 512 V — one catalogue from a single manufacturer
This is the master index of the HGU battery platform: every chemistry, every form factor, every voltage class we ship. If you are sizing a new backup plant or rationalising an existing spare-parts list, the HGU lineup gives you one part number for the small 12 V alarm cell and one part number for the megawatt-hour lithium cabinet — and every model in between is designed to be replaced or upgraded without changing your racking, cabling or float-voltage recipe.
The HGU series is the export brand of HG upsboss (Shenzhen Shengpuwei Industrial Co., Ltd.) for stationary backup batteries. It covers sealed lead-acid in three chemistries — AGM, GEL and lead-carbon — plus a LiFePO4 cabinet system for data-centre DC plants. Every model uses the same VRLA separator technology, the same case and terminal families, and the same CE / UL / IEC documentation kit. The result is a single platform you can deploy across telecom central offices, IT rooms, edge nodes, solar hybrid sites and industrial control cabinets, with one common float-voltage profile and one common procurement workflow.
79 models across 7 sub-families
Three lead-acid chemistries (AGM, GEL, lead-carbon) plus LiFePO4
Voltage range: 2 V cells, 12 V monoblocs, 51.2 V lithium modules, 192–512 V DC lithium cabinets
Capacity range: 4.5 Ah to 3000 Ah (lead-acid), 51.2 kWh to 102.4 kWh per cabinet (lithium)
Float design life 8–15 years depending on family
One terminal hardware tree, one connector family, one documentation pack
The HGU lineup is engineered for sites where DC backup is a regulated utility, not an afterthought:
Telecom central offices, base stations and FTTx nodes
UPS plants for server rooms, edge data centres and IT closets
EPS and emergency-lighting circuits
Fire-alarm, access-control and security panels
Renewable hybrid storage, off-grid PV and microgrid buffer
Industrial SCADA, instrumentation and railway signalling
Power plants, substations and process-control rooms
Single SKU tree from 4.5 Ah alarm cells to 102.4 kWh lithium cabinets
Common float/equalise recipe across the lead-acid families
Single datasheet format, single test-report template
One spare-parts stocking plan across your estate
AGM monobloc — float standby, infrequent discharges
Tubular GEL — daily cycling, partial state-of-charge, solar hybrid
Lead-carbon — hybrid storage with frequent micro-cycles
LiFePO4 cabinet — high-C rate, frequent cycling, data-centre DC bus
Factory pre-charge, capacity test and date-code printed at cell level
CE / UL / IEC 60896 / IEC 62619 documentation pack shipped with every shipment
UN2800 packaging classification and MSDS on file
Two-year shelf-life guarantee from date of manufacture
VRLA separator — AGM, GEL or lead-carbon depending on chemistry
ABS container and cover, flame-retardant to UL94 V-0 on request
One-way pressure-relief valve with flame arrester on every cell
Float voltage profile 2.23–2.27 V/cell at 25 °C, temperature-compensated -3 mV/°C/cell
Operating temperature -20 °C to +45 °C (recommended 20–25 °C)
Self-discharge below 3 % per month at 25 °C
Storage re-charge interval 6 months at 25 °C, 3 months at 35 °C
Cycle life ≥ 1500 cycles at 50 % DoD (model-dependent)
Torque on terminal bolts: 4–6 N·m (F1/F2/F3), 6–8 N·m (F12/F16), 10–12 N·m (F20)
Pick the family that matches your duty cycle and DC-bus voltage
| Family | Chemistry | Voltage class | Capacity range | Models | Best fit |
|---|---|---|---|---|---|
| HGU Series | AGM / GEL VRLA | 2 V cells | 200 – 3000 Ah | 12 | Large UPS plants, telecom central-office DC plants |
| HGU-12V | AGM VRLA | 12 V monobloc | 4.5 – 250 Ah | 34 | Small UPS, alarm panels, security, instrumentation |
| HGUX | AGM VRLA high-power | 12 V monobloc | 28 – 1250 W/cell | 19 | 15-minute UPS discharge, ride-through |
| HGUF | AGM VRLA front-terminal | 12 V monobloc | 55 – 190 Ah | 4 | 19-inch telecom / network cabinets |
| HGUG | Tubular GEL VRLA | 2 V and 12 V | 38 – 3000 Ah | 20 | Renewable cycling, telecom hybrid, off-grid PV |
| HGUC | Lead-carbon VRLA | 2 V and 12 V | 65 – 2000 Ah | 12 | Hybrid microgrid, frequent micro-cycle storage |
| HGUHVC | LiFePO4 cabinet | 192 – 512 V DC bus | 51.2 – 102.4 kWh / cabinet | 2 | Data-centre UPS, AI compute, HVDC plants |
Standby float duty (rare discharge): HGU 2 V cells, HGU-12V monobloc, HGUX high-power
Daily cycling (solar, microgrid, hybrid): HGUG tubular GEL, HGUC lead-carbon
Front-cabinet access (19-inch rack): HGUF front-terminal
High-rate discharge (15-minute UPS): HGUX
Long-life with low maintenance: HGUG tubular GEL
Partial state-of-charge operation: HGUC lead-carbon
Lithium-ion retrofit for data-centre DC bus: HGUHVC
Float voltage: 2.23–2.27 V/cell at 25 °C, compensated -3 mV/°C/cell
Equalise / cycle charge: 2.30–2.40 V/cell for up to 24 h
Operating temperature: -20 °C to +45 °C (recommended 20–25 °C)
Self-discharge: less than 3 % per month at 25 °C
Storage re-charge interval: 6 months at 25 °C, 3 months at 35 °C
Cycle life: ≥ 1500 cycles at 50 % DoD, model-dependent
Torque on terminal bolts: 4–6 N·m (F1/F2/F3), 6–8 N·m (F12/F16), 10–12 N·m (F20)
Type-test report (capacity, internal resistance, high-rate discharge)
Material Safety Data Sheet (MSDS) and UN2800 transport certificate
CE declaration of conformity, UL recognition letter (where applicable)
Installation, commissioning and float/equalise commissioning card
Recommended torque, cabling and racking layout drawing
Spare-parts list matched to the cells you actually received
Every HGU cell leaves the Shenzhen factory with a laser-etched date code, a traceable batch number and a printed capacity-test summary. Plates are formed in-house; AGM separators, GEL electrolyte and carbon-enhanced negative paste are mixed to proprietary recipes. Incoming raw materials are vendor-qualified; finished cells are 100 % capacity-tested before packing. The same factory builds the OEM packs for several Chinese and European UPS brands, so the production line is volume-proven rather than pilot-scale.
HGU cells are UN2800 classified, packed in heat-treated wooden cases on ISPM-15 pallets, and shipped from Shenzhen Yantian or Shekou under FOB, CIF or DAP terms. Typical lead time is 15–25 days for stock models and 30–40 days for special builds. We prepare the commercial invoice, packing list, certificate of origin and the FORM-A / FORM-E / FORM-FTA preferential certificates you need for your destination market.
HG upsboss is the export brand of Shenzhen Shengpuwei Industrial Co., Ltd., a battery and UPS-systems manufacturer based in Shenzhen, China. We design, build and export VRLA, GEL, lead-carbon and LiFePO4 backup batteries for UPS, EPS, telecom, data-centre and renewable-storage operators in more than 60 countries. Every HGU-series battery ships with type-test reports, full BMS integration where applicable, and the CE / UL / IEC documentation you need for customs clearance and end-user acceptance.
All product specifications, images and documentation published on this page are the property of HG upsboss / Shenzhen Shengpuwei Industrial Co., Ltd. and are intended for legitimate procurement, engineering and integration use. Reproduction for counterfeit, misbranding or unauthorised resale is prohibited. Specification values are typical at 25 °C and may vary within published tolerances. Battery installations must comply with local electrical, ventilation and transport regulations.
Yes — every HGU sub-family uses the same 2 V cell float-voltage window (2.23–2.27 V/cell at 25 °C), so a 2 V cell string from the HGU Series can share a DC bus with a 12 V monobloc from HGU-12V or a lithium cabinet from HGUHVC provided the overall DC-bus voltage is matched. Most operators standardise on one chemistry per string but use HGU across multiple strings.
For standby float duty, the 2 V cells in the HGU Series are rated up to 15 years at 25 °C. HGUG tubular GEL reaches the same envelope with the added benefit of deeper cycling when needed. HGUX high-power monoblocs deliver 12 years at 25 °C; HGUF front-terminal and HGU-12V monoblocs are rated 8–12 years.
For daily cycling with frequent partial state-of-charge operation, use HGUG tubular GEL (1500 cycles at 50 % DoD) or HGUC lead-carbon (over 4000 cycles at 50 % PSoC). For pure peak-shaving or short-burst solar smoothing, the HGU Series 2 V cells are also a proven choice at much lower unit cost.
Sealed VRLA cells are classified UN2800 non-spillable and are eligible for IATA air transport on most routes, subject to airline and destination-state approval. We provide the MSDS, the UN2800 test summary and the air-waybill description text you need.
All HGU cells ship factory-charged and ready to install. Dry-charged shipment is available on request for long-sea-voyage orders where shelf life before commissioning matters.
Standard warranty is three years from date of shipment for lead-acid families (HGU, HGU-12V, HGUX, HGUF, HGUG, HGUC) and five years for the HGUHVC lithium cabinet, conditional on storage, commissioning and float-voltage records being kept.
Yes — OEM branding (your logo, your part number, custom label) is available from a one-pallet minimum order for any HGU family. Lead time adds 10–15 days.
HG upsboss is the export brand of Shenzhen Shengpuwei Industrial Co., Ltd., registered in Shenzhen, Guangdong, China. Sales, technical support and after-sales service are handled from the same campus, with regional agents in the Middle East, Africa and South America. Use the Request a Quote form above to start a project.
Contact: Frank Zhang
Phone: +86-135 5688 8641
Email: frank@upsboss.com
Add: Jufeng Road, Guangming Street, Guangming District, Shenzhen City, Guangdong Province, China
We chat