High-Frequency Modular UPS

HPM 100kVA Modular UPS

  • Model: HPM100
  • Specification: 100kVA Hot-Swappable Power Module
  • Size: 442×750×130mm
  • Weight: 50Kg
  • Description: HG HPM series 100kVA modular online UPS adopts AI-enhanced double-conversion topology, delivering peak 99% efficiency under ECO mode. It features N+1 hot-swappable redundant modules and a 138~485Vac ultra-wide input voltage range. Fully certified to CE, TUV and IEC62040 standards, the unit achieves seamless synchronization with all types of diesel generators. Designed for mission-critical power backup in global hyperscale IDCs, financial hubs, energy facilities, military bases and transportation infrastructure. We operate local after-sales teams across Europe, Southeast Asia, the Middle East, Africa and the Americas, with standardized global warranty policies.
  • Online ordering

HG Group HPM Series High Frequency Modular UPS (100kVA Power Module)

1. Product Overview

      HG Group HPM 100kVA modular UPS adopts AI-powered online double-conversion architecture with high-density 100kVA hot-swappable power modules.

      This full product line is engineered exclusively for medium and hyperscale cloud data centers, enterprise headquarters and critical industrial facilities worldwide.

      Its built-in full-grid self-adaptive algorithm automatically mitigates voltage sags, surges, harmonic distortion and other grid disturbances from unstable overseas public power networks, continuously supplying clean pure sine-wave power to high-performance computing hardware, servers and precision core loads. All power, bypass and control modules support online hot swap.

      Capacity expansion or faulty module replacement can be completed without cutting power to downstream loads, fully catering to unmanned lights-out data center operation models. The battery system supports flexible configuration of 30 to 50 units of 12V batteries, compatible with both lead-acid and lithium energy storage systems. It maintains stable synchronous linkage with various diesel generators for remote mining, energy and factory sites across emerging global regions.

      The unit reaches ≥97% efficiency in standard online mode and peaks at 99% in ECO energy-saving mode. It fully complies with EU ErP energy efficiency regulations and effectively cuts long-term electricity operating costs for global data center facilities.

2. Global Application Scenarios

   ● Hyperscale Cloud & Colocation Data Centers (New IDC Clusters in EU & Southeast Asia)

   ● Global Financial Headquarters, Securities Trading Floors, Cross-Border Bank Disaster Recovery Sites

   ● Power Stations, Oil & Gas Mining Sites, Renewable Energy Plants (Middle East & North American Industrial Zones)

   ● Government Command Centers, Military Installations, Aerospace Test Laboratories

   ● National Railways, Airports, International Stadium Mission-Critical Power Systems

Regional Adaptation Notes

   ● European Region: Fully compliant with EU EMC and energy efficiency standards, enabling smooth customs clearance for all EU member states.

   ● Middle East & North Africa: Optimized wide-voltage and high-temperature hardware design to suit harsh desert industrial operating environments.

   ● Southeast Asia & Africa: Robust harmonic suppression capability to offset unstable local public power grids.

   ● North America: Embedded generator synchronization control logic, fully compatible with mainstream local diesel generator units.


3. Four Core Competitive Advantages

3.1 Extreme Stability for Complex Global Grids

    ● 138~485Vac ultra-wide input voltage range; full power output above 305Vac, linear power derating between 138Vac and 305Vac; 40~70Hz ultra-wide frequency compatibility with legacy and modern diesel generators.

    ● Full digital DSP control, input current THDi ≤3%, output voltage THD ≤1% under linear loads, isolating grid interference to protect high-end IT infrastructure.

    ● Tiered intelligent overload protection: Continuous operation for 60 mins at 110% load, 10 mins at 125% load, 1 min at 150% load; automatic bypass transfer within 200ms for loads exceeding 150% to eliminate server downtime risks.

    ● Triple redundant design for power, bypass and control subsystems with zero single point of failure, meeting the highest reliability benchmarks for financial and military-grade projects.


3.2 High Efficiency & Global Energy Compliance

    ● Standard mode efficiency ≥97%, peak ECO mode efficiency up to 99%, drastically lowering data center PUE and long-term operational expenditure.

    ● Intelligent module sleep & rotational operation under light loads, slashing idle power consumption for multi-module cabinets.

    ● Input power factor up to 0.99 with minimal reactive power loss; no additional reactive compensation cabinets required to save floor space and upfront procurement costs.

    ● Certified against all international energy efficiency standards, eliminating compliance barriers for exports to European and American markets.


3.3 AI Intelligent Unattended Remote O&M

    ● 10-inch HD touchscreen delivers full visual real-time monitoring of input/output parameters, battery status, module operating data and ambient temperature.

    ● Comprehensive communication interfaces including CAN, RS485, RJ45 Ethernet, dry contact alarm terminals and an expandable SNMP slot. Supports standard Modbus RTU / TCP protocols for seamless integration with mainstream global DCIM and 3D visualization monitoring platforms.

    ● AI intelligent battery management system delivers early warning for single-cell faults; full battery pack replacement is not mandatory, reducing overseas operation and maintenance expenses.

    ● Automatic fault logging and remote alarm push notifications; 24/7 cross-border remote diagnostic support eliminates the need for permanent on-site engineers at overseas branch facilities.


3.4 Modular Design for Easy Global Delivery & Maintenance

    ● All core modules support hot swapping; faulty modules can be fully replaced within 5 minutes without full cabinet shutdown.

    ● Multiple cabinet form factors covering 300kVA to 1200kVA; single cabinet maximum capacity reaches 1200kVA, occupying over 50% less floor space compared with conventional monolithic UPS equipment.

    ● Neutral-line independent battery architecture supports mixed retrofits of old and new battery banks; legacy computer room upgrades do not require complete battery bank replacement.

    ● Globally standardized interchangeable spare parts, with regional local warehouses cutting overseas after-sales lead times significantly.


4. Complete Technical Specifications

4.1 Quick Reference Spec Sheet 

ItemTechnical Parameter
Single Power Module Capacity100kVA
Full Cabinet Capacity Range300kVA ~ 1200kVA
Input Format3 Phase 5 Wire (3P+N+PE) 380/400/415Vac
Input Voltage Range138~485Vac
System EfficiencyNormal ≥97% / ECO ≥99%
Output Power Factor1.0
Battery Configuration30~50pcs 12V, DC 360~600V
Protection ClassIP20
Operating Temperature0℃ ~ 40℃
Operating Noise (1m)<68dB
Global CertificationsCE, TUV, IEC62040, ISO9001, ISO14001, RoHS

4.2 Full Detailed Electrical Parameters

Main Input

   ● Connection Mode: 3 Phase 5 Wire (3P+N+PE)

   ● Rated Line Voltage: 380 / 400 / 415Vac

   ● Operating Voltage Band: 138~485Vac; full power output at 305~485Vac, linear derating below 305Vac

   ● Input Frequency Range: 40~70Hz

   ● Input Power Factor: >0.99

   ● Input Current THDi: <3% @ 100% Linear Load

Bypass Input

   ● Rated Bypass Voltage: 380 / 400 / 415Vac

   ● Adjustable Voltage Thresholds: Upper limit configurable +10%~+25%, lower limit configurable -10%~-45%

   ● Frequency Synchronization Tracking Range: ±10Hz customizable

Battery System

   ● DC Operating Voltage Band: 360 ~ 600 VDC

   ● Standard Battery Layout: 30~50pcs 12V lead-acid batteries (even quantity configurable, factory default: 40pcs)

   ● Functionality: Intelligent three-stage charging management, compatible with high-voltage lithium battery retrofit projects

Output Performance

   ● Rated Line Output Voltage: 380 / 400 / 415Vac

   ● Output Power Factor: 1.0

   ● Auto Frequency Adaptation: 50 / 60Hz

   ● Output Voltage THD: <1% (Linear Load), <2% (Non-linear Load)

   ● Dynamic Load Response: Voltage fluctuation <5% under 0~100% step load, recovery duration <20ms

   ● Overload Protection Logic:

      110% Load: Bypass transfer after 60 mins

      125% Load: Bypass transfer after 10 mins

      150% Load: Bypass transfer after 1 min

      Load exceeding 150%: Instant bypass transfer within 200ms

Environmental Parameters

   ● IP Ingress Rating: IP20

   ●  Standard Operating Ambient Temperature: 0℃ ~ 40℃

   ●  Storage & Transit Temperature (Batteries Excluded): -25℃ ~ 55℃

   ●  Relative Humidity: 0~95%RH, non-condensing

   ●  Full-Power Operating Altitude: ≤1500m; linear power derating above 1500m

   ●  Acoustic Noise Level (1 Meter Distance): <68dB

Communication Interfaces

  ● CAN Bus, RS485, RJ45 Ethernet, dry contact alarm terminals, expandable SNMP slot, dedicated temperature sensor port


4.3 Cabinet Dimension & Weight Table

Model No.Total CapacityCabinet W×D×H (mm)Total Weight (kg)Single 100kVA Module Size (mm)Module Weight (kg)
HPM300/100300kVA600×1000×2000226442×750×13050
HPM400/100400kVA600×1000×2000246442×750×13050
HPM500/100500kVA800×1000×2000340442×750×13050
HPM600/100600kVA800×1000×2000360442×750×13050
HPM800/100800kVA1600×1000×2000715442×750×13050
HPM1000/1001000kVA1600×1000×2000755442×750×13050
HPM1200/1001200kVA1600×1000×2000825442×750×13050


5. Product Visual Gallery

Matching Supporting Products

   ●   HGU VRLA Lead-acid Energy Storage Battery

   ●  HGUHVC High Voltage Lithium Storage System

   ●  SDZ & SHJ Row Precision Air Conditioner

   ●  SDCT Intelligent Row Power Cabinet


6. Hyperscale Data Center Integrated Power Solution

    HG Group HPM 100kVA modular UPS serves as the core power hardware for turnkey prefabricated data center solutions. Paired with precision cooling, intelligent power distribution, complete energy storage and centralized monitoring systems, we provide factory pre-assembled, pre-commissioned one-stop delivery services for global clients.

Solution Advantages

   ● Factory pre-assembly, pre-wiring and pre-testing; on-site overseas commissioning completed within 4~6 working days.

   ● Full N+1 redundant power architecture with zero single point of failure, meeting the 99.999 high availability standard for financial and computing industry facilities.

   ● Closed cold & hot aisle thermal design paired with high-efficiency UPS units, limiting overall facility PUE below 1.3 to align with global green data center standards.

   ● Centralized full-system remote O&M, ideal for large-scale unmanned overseas computer room projects.

Standard Matching Configuration Reference

    HPM1200/100 Modular UPS + 12.5kW Row Precision Air Conditioner + SPW 12V 200Ah Battery Bank + SLT Intelligent Row Cabinet + 3D DCIM Visual Monitoring Platform


7. Global Frequently Asked Questions

Q1: Is the HPM 100kVA UPS compatible with diesel generator sets?

A1: Yes. The unit supports an ultra-wide 40~70Hz input frequency band with embedded generator synchronous control logic. It generates no surge impact during generator startup and shutdown, compatible with all mainstream global diesel generator models.

Q2: Does this UPS hold CE and IEC certifications for EU export clearance?

A2: The complete system carries full CE, TUV, IEC62040 and RoHS certification, fully compliant with EU electrical safety and energy efficiency regulations, with zero customs clearance barriers for all EU member states.

Q3: Are power modules hot-swappable? Is full cabinet shutdown required to replace faulty modules?

A3: All power, bypass and control modules support live online hot swapping. Faulty modules can be replaced without cutting power to downstream IT loads.

Q4: Where are HG Group’s overseas spare parts warehouses and local technical engineers stationed?

A4: Regional sales and service centers with dedicated spare parts stock are established across Europe, Southeast Asia, the Middle East, the Americas and Africa. We offer on-site commissioning alongside our standardized global warranty policy.

Q5: What is the maximum rated operating temperature? Can it be deployed in Middle East desert data centers?

A5: Standard operating temperature range is 0℃~40℃. Custom high-temperature enhanced variants are available for sustained 45℃ desert operating environments.

Q6: What is the maximum number of identical UPS units supported for parallel expansion?

A6: Up to 6 matching HPM series units can be paralleled to implement N+X redundant architecture, satisfying capacity expansion requirements for thousands-of-rack hyperscale data centers.

Q7: Is the communication system compatible with mainstream international monitoring platforms?

A7: Standard RS485, CAN and Ethernet ports are equipped, supporting Modbus RTU / TCP industrial protocols for seamless integration with all globally mainstream DCIM and 3D visualization monitoring software.


8. Document Download & Global Inquiry

Downloadable English PDF Documents

    ●  PDF File  HPM 100kVA UPS Official English Datasheet

    ●  PDF File  Global Installation & Operation Manual for HPM Modular UPS Series

Submit Inquiry for Custom Quotation & Technical Support

      Click the button below to visit our dedicated feedback portal. Share your project specifications and contact details, and our global sales team will deliver a customized power solution and factory-direct quotation within 24 working hours.

Go to Feedback Page


9. Global Sales & After-sales Support

Global Service Network

      HG Group operates independent sales and after-sales hubs across Europe, Southeast Asia, the Middle East, North & South America and Africa, with localized spare parts inventory and multilingual professional technical engineers stationed in each regional territory.

Global After-sales Policy

   ● Standard 3-year global full cabinet warranty; every individual 100kVA power module carries a separate 5-year warranty.

   ● Local regional spare parts warehouses guarantee component delivery to project sites within 48 hours upon request.

   ● 24/7 multilingual remote technical support (English, Arabic, Spanish).

   ● Overseas on-site equipment commissioning and professional data center operation training services.

OEM & ODM Customization Service

      We deliver comprehensive OEM / ODM customization for global system integrator brands, including private brand labeling, custom input/output voltage specs, tailored communication protocols, dedicated battery matching architectures and customized cabinet exterior design.

10. Related Products & Consultation