Welcome to HG Group official website – your trusted supplier of data center power solutions
PRODUCTS

High-Frequency Tower UPS

YDC Series 3P1P High Frequency Tower UPS

  • Model: YDC-SDT010L/015L/020L
  • Specification: 10kVA/15KVA/20kVA
  • Size: 190×660×330mm
  • Weight: 19.9/20.2/21.3Kg
  • Description: YDC series 3-phase input single-phase output high frequency tower UPS covers 10kVA/15kVA/20kVA three models, adopts online double conversion DSP full digital control. Input voltage 190-520Vac, output power factor 0.9, overall efficiency ≥90%, compact cabinet size 190×610×330mm, built-in LCD display panel. It has complete overload protection, intelligent battery management, rich communication ports including RS232/USB/EPO/SNMP optional. Ideal for government offices, SME branches, small data nodes, communication and precision instrument power backup, support global project delivery and customized OEM service.
  • Online ordering

YDC Series 3-Phase Input 1-Phase Output High Frequency Tower UPS (10kVA~20kVA)

Product Positioning: Light compact 3P1P online UPS, dedicated for office, branch outlets, small network room and precision instrument power protection

Full Model List: YDC-SD1010L(10kVA)、YDC-SD1510L(15kVA)、YDC-SD2010L(20kVA)

Display Configuration: All models built-in standard LCD display screen for local operation & data viewing

Unified Cabinet Dimension: 190×610×330mm

Execution Standard: Industrial UPS general technical specification


1. Product Overview

      Different from large-capacity 3P3P tower UPS, YDC series adopts three-phase input and single-phase output architecture, specially developed for scenarios with three-phase mains access but only single-phase terminal loads. It applies mature online double conversion + DSP full digital control algorithm, can actively filter grid voltage fluctuation, surge, harmonic and spike interference, output stable pure sine wave power for precision loads.

      The whole series adopts ultra-compact vertical tower structure with unified cabinet size, small floor space and neat appearance, suitable for placing inside ordinary server cabinets and narrow equipment corners. The built-in LCD screen can realize local parameter check, fault prompt and operation setting without external display device. Rich communication interfaces are reserved, SNMP card can be optionally installed to realize remote centralized monitoring of multiple distributed branch sites.

      With graded weight design for different capacities, the unit is easy for manual handling and on-site installation. Intelligent battery management function supports adjustable charging parameters, effectively prolongs battery service life and reduces daily operation and maintenance difficulty for scattered small power sites.


2. Three Core Product Advantages

2.1 Mature Digital Power Solution, Stable Power Quality

   ● Adopts industry-proven DSP full digital control for online double conversion topology, quickly suppresses various grid disturbances such as voltage deviation, surge and peak pulse.

   ● Input wide voltage range 190~520Vac, strong adaptability to unstable commercial mains in suburban areas and business parks.

   ● Output voltage regulation accuracy ±1%, THDi ≤3% for linear load, ≤5% for non-linear load, delivers clean power for servers, testing instruments and network equipment.


2.2 Compact Integrated Structure, Easy for Distributed Deployment

   ● Unified slim cabinet size 190×610×330mm, occupies very little floor area, beautiful appearance and space-saving.

   ● Light body weight: 19.9kg(10kVA)/20.2kg(15kVA)/21.3kg(20kVA), no special handling tool required for installation.

   ● Built-in LCD human-machine interface, independent operation without extra monitoring terminals, perfect for unattended branch offices.

2.3 Comprehensive Protection & Intelligent Operation Management

   ● Complete multi-level protection: input over/under voltage, output overload, short circuit, inverter fault, battery over-discharge protection; pre-start self-diagnosis function.

   ● Intelligent battery management: adjustable charging voltage, current and floating charge mode, automatic balance between battery strings.

   ● Standard RS232, USB, EPO dry contact interfaces, optional SNMP/NetCard expansion, support remote cloud monitoring and centralized management of multi-site UPS units.


3. Main Application Scenarios

     1.Government and public institution offices, SME regional branch offices, bank community outlets

     2.Small edge data nodes, branch network computer rooms, communication transmission equipment

     3.Industrial automation control terminals, testing laboratory precision instruments

     4.Smart building weak current system, community monitoring and access control power backup


4. Full Series Model Parameter Table(Strictly follow manual data)

ModelRated CapacityDisplayCabinet W×D×H(mm)Net Weight(kg)Input VoltageOutput PFOverall EfficiencyMax Battery Cells
YDC-SD1010L10kVA/9kWBuilt-in LCD Screen190×610×33019.9190-520Vac0.9≥90%16~20pcs
YDC-SD1510L15kVA/13.5kWBuilt-in LCD Screen190×610×33020.2190-520Vac0.9≥90%16~20pcs
YDC-SD2010L20kVA/18kWBuilt-in LCD Screen190×610×33021.3190-520Vac0.9≥90%16~20pcs


4.1 General Electrical Parameters

Input

   ● Wiring: 3P+N+PE three phase five wire

   ● Rated input voltage: 380/400/415Vac

   ● Input voltage range: 190~520Vac

   ● Input frequency: 50/60Hz±5Hz

   ● Input power factor ≥0.94

Output

   ● Output wiring: 1W+N+PE single phase three wire

   ● Rated output voltage: 220/230/240Vac

   ● Output power factor: 0.9

   ● Voltage regulation accuracy: ±1%

   ● Frequency: Mains mode synchronous tracking; battery mode (50/60±0.1)Hz

   ● Voltage distortion: ≤3%(linear load), ≤5%(non-linear load)

   ● Overall efficiency ≥90%

   ● Overload capacity:

      Mains mode: 110% for 30min;130% for 10min;150% for 30s;>150% transfer to bypass in 200ms

      Battery mode:110% for 10min;130% for 1min;150% for 10s;>150% transfer to bypass in 200ms

Battery

   ● Battery quantity: 16~20 cells optional

   ● Default charging current 1A~12A adjustable

   ● Transfer time: Mains to battery 0ms; battery to bypass ≤200ms

Environment

   ● Operating temperature: 0℃~40℃

   ● Storage temperature: -15℃~60℃(no battery)

   ● Humidity: 20~95% non-condensing

   ● Max full-load altitude ≤1000m

Communication

   ● Standard ports: RS232, USB, EPO; SNMP / NetCard optional


5. Matching Auxiliary Solutions & Global Custom Service

Supporting Products

     1.Matching 12V valve-regulated lead-acid battery packs

     2.Wall-mounted small battery cabinet for branch sites

     3.Lightweight remote UPS centralized monitoring platform

     4.EPO emergency power-off linkage system

Customization Service

      Support multi-language LCD firmware, charging parameter adjustment, customized voltage specification, OEM logo printing. Provide remote technical guidance for chain outlets and multi-branch projects, support batch export order delivery.


6. FAQ

Q1: What is the advantage of 3P1P structure compared with single-phase input UPS?

A1: It uses three-phase mains power supply to balance grid load, suitable for buildings with three-phase incoming line while most loads are single-phase office equipment, avoiding three-phase unbalance problem.

Q2: Are three models the same in cabinet size?

A2: Yes, 10/15/20kVA share unified 190×610×330mm cabinet, only net weight differs slightly, convenient for unified installation and cabinet layout planning.

Q3: Can it realize remote monitoring for multiple branch offices?

A3: Optional SNMP network card, connect to centralized monitoring platform to manage distributed UPS devices of all branches uniformly.

Q4: How about the overload performance under battery mode during power failure?

A4: Battery mode has strict graded overload protection, fast bypass switching for severe overload to protect host and load safety.

Q5: Suitable for bulk procurement of chain commercial projects?

A5: Compact unified appearance, simple installation and consistent parameters, very suitable for centralized bidding procurement of chain stores and institutional branches.


7. Document Download & After-Sales Commitment

Downloadable Files

     1.YDC 10-20kVA 3P1P UPS English datasheet

     2.Installation, wiring and communication configuration manual

     3.Full set of product inspection reports

Warranty

   ● 3-year whole machine global warranty

   ● 24/7 remote technical support, batch project on-site debugging service available

   ● Provide OEM private label customization for global distributors and system integrators