EP-JJ Series 3-Phase Input 3-Phase Output High Frequency Rackmount UPS (10kVA~40kVA)
Product Positioning: 19-inch standard rack online UPS, designed for government branches, hospital equipment rooms, telecom stations, campus small data nodes and precision instrument power protection
Full Model List: EP-JJ010L / EP-JJ015L / EP-JJ020L / EP-JJ030L / EP-JJ040L
Display Specification: All models built-in embedded touch color LCD for local operation & status monitoring
Unified Cabinet Dimension: 438×728×130mm (W×D×H)
Executive Design: Support 3P3P / 3P1P / 1P1P wiring mode switch for 10/15/20kVA models, max 4 units parallel operation
1. Product Overview
Different from floor-standing tower UPS products like EP-KL and YDC series, EP-JJ is specially optimized for standard server cabinet installation, adopting advanced DCS digital online double conversion control technology. It supports flexible input and output wiring modes, has complete intelligent monitoring and network management functions, can adapt to complex grid fluctuation effectively, features high input power factor, low current harmonic distortion and wide voltage tolerance.
The embedded touch color screen integrates real-time data display, fault alarm and parameter setting, no extra local control terminal is required. The whole series supports multi-unit parallel connection with shared battery group, convenient for capacity expansion of growing IT loads. Rich communication expansion options meet centralized O&M demands of distributed branch computer rooms for telecom, finance and public institutions. Compact rack size saves cabinet space, neat layout for standardized machine room construction.
2. Four Core Product Advantages
2.1 Stable Digital Control & Excellent Grid Adaptability
● DCS full digital DSP control architecture improves overall operation stability
● Built-in PFC correction, input power factor reaches 0.99, effectively reduce grid reactive loss
● Ultra-wide 138~485Vac input voltage range, adapt to unstable power supply of suburban and old industrial areas
2.2 Flexible Wiring & Parallel Capacity Expansion
● 10/15/20kVA models support switching among 3P3P, 3P1P, 1P1P modes for diversified on-site wiring conditions
● Max 4 units parallel connection and shared battery bank, flexible capacity upgrade without replacing whole machine
● Intelligent charging scheme, battery strings 30~50 sections adjustable for different backup duration demands
2.3 Intelligent O&M & Rich Communication Expansion
● Embedded touch LCD for real-time running data viewing and fault record query
● Standard RS232, RS485 ports; optional parallel card, SNMP card and dry contact card for remote centralized monitoring
● Complete event log function, trace historical faults to realize controllable operation management
2.4 Rack Design for Standard Machine Room Deployment
● Unified 19-inch rack dimension 438×728×130mm, fits mainstream server cabinets
● Optimized internal air duct, running noise ≤55dB, suitable for office-type branch machine rooms
● Fast zero switching between mains / bypass / battery mode, guarantee uninterrupted power for key loads
3. Typical Application Scenarios
1.Government agency branch computer rooms, public institution IT equipment rooms
2.Hospital ward monitoring system, medical precision testing instruments
3.Campus network center, education laboratory power protection
4.Telecom base stations, financial securities outlet data nodes
5.Small and medium enterprise internal data center, industrial automatic control terminals
4. Full Series Parameter Comparison Table (Strict Manual Data)
| Model | Rated Capacity | Display | Cabinet W×D×H(mm) | Net Weight(kg) | Max Charging Current | Noise | Max Parallel Quantity |
|---|---|---|---|---|---|---|---|
| EP-JJ010L | 10kVA/9kW | Embedded Touch LCD | 438×728×130 | 23.2 | 25A | ≤55dB | 4 |
| EP-JJ015L | 15kVA/13.5kW | Embedded Touch LCD | 438×728×130 | 23.7 | 25A | ≤55dB | 4 |
| EP-JJ020L | 20kVA/18kW | Embedded Touch LCD | 438×728×130 | 24.1 | 25A | ≤55dB | 4 |
| EP-JJ030L | 30kVA/27kW | Embedded Touch LCD | 438×728×130 | 26.3 | 70A | ≤55dB | 4 |
| EP-JJ040L | 40kVA/36kW | Embedded Touch LCD | 438×728×130 | 29.2 | 70A | ≤55dB | 4 |
4.1 Universal Electrical Parameters
Input
● Wiring: 3-phase 5-wire / single phase 3-wire (10/15/20kVA mode switchable); 3-phase 5-wire for 30/40kVA
● Rated input voltage: 380/400/415Vac (phase-phase), 220/230/240Vac (phase-neutral)
● Input voltage range: 138~485Vac
● Frequency: 40~70Hz
● Input PF≥0.99, THDi≤3% linear load, ≤5% non-linear load
● Generator access supported, adjustable bypass voltage threshold
Output
● Rated output voltage: 380/400/415Vac
● Output PF=0.9
● Frequency: mains mode multi-range adjustable; battery mode (50/60±0.1)Hz
● Voltage THD≤2% linear load, ≤4% non-linear load
● Overall efficiency>95%
● Overload:110% for 60min,125% for 10min,150% for 1min then transfer to bypass
Battery
● DC voltage: ±180V~±300Vdc, 30~50 battery cells optional
● Max charging current: 25A(10/15/20kVA),70A(30/40kVA)
● Transfer time: mains-bypass 0ms, mains-battery 0ms
Environment
● Operating temp:0~40℃, storage temp:-25~55℃
● Humidity:0~95% non-condensing, max altitude ≤1500m
Communication
● Standard RS232,RS485; parallel card,dry contact card,SNMP card optional
5. Supporting Solutions & Custom Service
Matching Auxiliary Products
1.Matched series valve-regulated lead-acid battery packs
2.Rack-mounted battery cabinet for machine room layout
3.UPS centralized remote monitoring system
4.EPO emergency power-off linkage module
Global Customization
Support multi-language LCD firmware, customized charging parameters, OEM logo marking, pre-sales cabinet layout consulting, on-site parallel commissioning for large branch network projects.
6. FAQ
Q1: What is the difference between EP-JJ rack UPS and EP-KL tower UPS?
A1 EP-JJ adopts 19-inch rack structure for cabinet installation, supports multi-mode wiring and multi-unit parallel expansion, oriented to standardized machine room scenarios; EP-KL is floor-standing tower type for scattered workshop and office sites.
Q2: Which models support wiring mode switching?
A2 EP-JJ010L/015L/020L can switch between 3P3P/3P1P/1P1P modes, 30kVA and 40kVA are fixed 3P3P wiring.
Q3: How many units can be connected in parallel?
A3 Maximum 4 units parallel operation with shared battery group for step-by-step capacity expansion.
Q4: Is the noise suitable for office branch machine rooms?
A4 Running noise ≤55dB, low hum and fully meets the noise limit of non-industrial machine rooms.
Q5: Can it connect to centralized telecom monitoring platform?
A5 Optional SNMP network card to upload operating data and fault alarms to upper-level management platform.
7. Document Download & After-Sales
Download Files
1.EP-JJ 10-40kVA Rack UPS English Datasheet
2.Cabinet Installation & Parallel Configuration Manual
3.Full set of product qualification & test reports
Warranty
● 3-year global whole machine warranty
● 24/7 multilingual remote technical support
● Provide OEM private label service for system integrators and overseas distributors